| dc.description.abstract | This study aims to determine the sizing of the various structures that make up the Ain Beida wastewater treatment plant. The design is based on the expected influent load projected for the year 2050. The treatment system operates using biological disk technology. We estimated the daily wastewater flow rates and the equivalent population. Based on this data, we calculated the required sizes of the treatment basins and the optimal dimensions of the biological disks, ensuring compliance with current environmental standards. The study also considers future expansion needs in response to the city’s anticipated demographic growth. | en_US | 
| dc.identifier.uri | http://dspace.univ-temouchent.edu.dz/handle/123456789/6810 | |
| dc.language.iso | fr | en_US | 
| dc.subject | station d’épuration, dimensionnement, disque biologique, AIN BEIDA. | en_US | 
| dc.subject | waste water treatment plant, sizing, biological disc, AIN BEIDA, | en_US | 
| dc.title | Dimensionnement d'une station d'épuration a bio disque à AIN BEIDA commune de HAMMAM BOUHDJER | en_US | 