Our work aims to size a future wastewater treatment plant for the locality of AIN BEIDA for the
horizon of 2051.
This dimensioning is based on two biological treatment processes: "activated sludge and SBR", in
order to compare them and choose the most compact one, by calculating the wastewater flow rates by
2051, and a complete dimensioning of all basins for each process.
6
After the interpretation of the results and the comparison between the two processes concerning the
total surface occupied by the basins and the closing wall, we chose the SBR as a process because of
compactibility by comparing with the activated sludge.
To finalize our work, we used software such as:
- Autocad to apply the calculations obtained on plans.
- The calculation and simulation software for adduction by discharge to determine the operating point
of the pumping system and the mathematical equation of the chosen pump.