Experimental and simulation study of multichannel air gap membrane distillation process with two types of solar collectors

dc.contributor.authorMarni Sandid, Abdelfatah
dc.contributor.authorBassyouni, M
dc.contributor.authorNehari a, Driss
dc.contributor.authorElhenawy, Yasser
dc.date.accessioned2023-12-09T07:26:13Z
dc.date.available2023-12-09T07:26:13Z
dc.date.issued2021-06
dc.description.abstractSolar thermal energy for membrane distillation desalination is a green and safe way for areas where water scarcity and solar irradiance are strongly correlated. In this paper, a commercial-scale of desalination plant was installed and tested to study the performance of a multichannel spiral-wound air gap membrane distillation module with an area of 14.4 m². Air gap membrane distillation desalination plant at Port Said university was powered by solar energy using flat plate and evacuated tube collectors. The model validation was carried out. The solar desalination systems were numerically simulated using the program TRNSYS under different weather conditions throughout the year. The influence of the main operating parameters (feed flow rate and inlet temperatures of evaporator and condenser) was investigated. Regression analysis agreed with experimental data fitting using a quadratic polynomial model with coefficients of determination (R²) values of 0.997, 0.972, and 0.999 for permeate flux, outlet feed temperature, and outlet coolant temperature, respectively. The results showed that the permeate flux of the air gap membrane distillation with the evacuated tube collectors was 18.81%–30.44% higher than flat plate collector, and its cost was 22.48% lower. The specific thermal energy consumption of the air gap membrane distillation system ranged from 158.83 kWh/m3 to 346.55 kWh/m3. The maximum gain output ratio reaches 4.4 at 52 °C, depending on the feed inlet temperature. The thermal efficiency of the air gap membrane distillation system is 72%. The proposed air gap membrane distillation system produced 28.78 m3/year of fresh drinking water at a cost of USD 14.73/m3 with remarkable reducing in carbon dioxide emissions by 7,274.45 kg/year.en_US
dc.identifier.citationhttps://doi.org/10.1016/j.enconman.2021.114431en_US
dc.identifier.urihttps://dspace.univ-temouchent.edu.dz/handle/123456789/1135
dc.language.isoenen_US
dc.publisherEnergy Conversion and Management 243(1-3):14en_US
dc.titleExperimental and simulation study of multichannel air gap membrane distillation process with two types of solar collectorsen_US
dc.typeMusical Scoreen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Experimental and simulation study of multichannel.pdf
Size:
91.96 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: