Etude et comparaison des performances d’un climatiseur individuel fonctionnant au R22 et R 410 A

dc.contributor.authorSELMA, Romaissaa Feriel
dc.contributor.authorNEGADI, Abedlfatah
dc.date.accessioned2024-03-10T09:20:24Z
dc.date.available2024-03-10T09:20:24Z
dc.date.issued2020
dc.description.abstractThis work presents the experimental of the air conditioner using coolants R22 and R410A. The effect of different performance analysis paramaters (refrigeration capacity, COP, compressor power, pressure ratio) have been studied for various evaporation temperature and ambient temperature. The experimental results obtained show that the refrigerant R22 is better than R410A in case of COP, refrigeration capacity, but for pressure ratio and compressor power the R410A shows best performance than R22. This refrigerant was replaced at the end of 2015 due to their severe environmental impact.en_US
dc.identifier.citationhttps://theses.univ-temouchent.edu.dz/opac_css/doc_num.php?explnum_id=3250en_US
dc.identifier.urihttp://dspace.univ-temouchent.edu.dz/handle/123456789/2906
dc.subjectR22, R410a, Performanceen_US
dc.titleEtude et comparaison des performances d’un climatiseur individuel fonctionnant au R22 et R 410 Aen_US