Analyse tridimensionnelle d'un capteur solaire plan muni d'ailettes décalées

En cours de chargement...
Vignette d'image

Date

Nom de la revue

ISSN de la revue

Titre du volume

Éditeur

Résumé

In this work, we numerically investigated the thermal and dynamic behavior of forced convection airflow inside a flat plate solar collector equipped with staggered rectangular fins. The continuity, momentum and energy equations are solved using the ANSYS Fluent code, based on the finite volume method. The k-ε turbulence model is used to simulate turbulence. This study examines the influence of fin number (0, 3 and 6 fins) and fin height (0.02 m, 0.05 m and 0.08 m) on the thermo-hydraulic performance of the collector, for different mass flow rates (0.02 to 0.06 kg/s). Performance is evaluated using the thermo-hydraulic criterion, which simultaneously accounts for heat transfer enhancement and pressure drop penalty."

Description

Citation