The distribution of domestic water remains a delicate issue and often complex for water
technicians and managers. Reason why we studied in this work the drinking water supply
network from the POS SUD EST II study area, South / East extension of the town of Ain
Témouchent. In this context, we have established a diagnosis of the network and studied its
sizing by the arbitrary method that we compared with our resizing by the Hardy-Cross
method. The simulation by Epanet showed that sizing by Hardy-Cross is more reliable than
the Arbitrary method in terms of flow conditions. Finally, we characterized the network by
ArcGIS a GIS software, where we made available to the manager a network control tool
that we have resized, for each node, section and structure in real time