dc.description.abstractThe objective of this study is to present the simulation of electrostatic field in a moving wave conveyor. Two simulation models were established and calculated using Flux2D software, for the two types of conveyors (two and three phases) with an air insulating film and kapton film. The simulation results show that the electric field is higher with air isolation film and it is diminished when we replace it by the kapton film in the two-phases or three-phases conveyor. Kapton film isolation is better than air isolation.en_US
dc.subjectelectrostatic field - Air - Kapton – travelling waves - Flux2D - simulationen_US
dc.titleSimulation du champ électrostatique dans un convoyeur à ondes mobilesen_US