dc.description.abstract | In this work, we present the principles fora heat exchanger design and for evaluating the performance of an existing exchanger. Two approaches are described, an analytical approach and a numerical approach. In the analytical approach, the KERN method is proposed. For the numerical process, Hysys software is used for design. Emphasis is placed on the sizing and design of a tube and shell type heat exchanger. | en_US |
dc.subject | exchanger, heat, tube, shell, simulation, design, KERN. | en_US |
dc.title | Dimensionnement d'un échangeur de chaleur tube et calandre par Aspen Hysys | en_US |